youtube twitter facebook linkedin
Info@wonclean.com / 013 960 7988

Cleanroom Other products

Atomized glass film

Electrified atomized glass is a brand-new technological product that can produce an atomizing effect on the glass surface by controlling electric current to protect privacy....

Request a Free Quote
Clear ↔ OpaqueOn-demand switching
< 1.2 s Switch72% / <2.5% transmittance
No BlindsNo contaminant traps
> 1M CyclesClass 0 fire rating

 

Atomized Glass Film: Switchable Privacy for Cleanroom Glass Partitions

The atomized glass film is a dynamic electrochromic interlayer laminated into cleanroom glass assemblies, switching on demand between transparent and opaque via low-voltage DC — delivering real-time privacy without mechanical blinds that trap contaminants. It is ideal for clean room full glass partition wall solutions in semiconductor fabs, biopharma aseptic suites and optical labs.

Deployed across our Malaysia prefabricated cleanrooms, it integrates with our clean room glass doors, clean room partition panels and cleanroom weighing cover — engineered by an experienced cleanroom manufacturer for clean room glass wall frameworks.

01 — Technical Specifications

Atomized Glass Film Specifications

Standard configuration for the Wonclean atomized glass film. Size, transmittance and control are all customizable to project and cleanroom classification requirements.

Atomized Glass Film — Standard Technical Data
Switching voltage DC 36–48 V (UL/IEC 62368-1 compliant)
Switching time < 1.2 s (full area, 25°C)
Light transmittance (ON/OFF) 72% / < 2.5% at 550 nm
Surface hardness ≥ 7H (ASTM D3363)
Operating temperature −10°C to +65°C
Lifespan > 1 million switch cycles
Fire rating BS 476-22:1987 Class 0 / EN 13501-1 B-s1,d0
Disinfection Compatible with IPA-based disinfectants
Outgassing No VOC outgassing
Integration Seamless with existing cleanroom partition systems (retrofit)

Values shown are standard/representative configurations. Confirm final certified figures (fire test, switching performance) against the project datasheet before specification — Wonclean issues a stamped datasheet with every quotation.

02 — Construction

Atomized Glass Film Construction

The electrochromic interlayer is the engineering secret. Laminated between glass, it switches clear-to-opaque in under 1.2 seconds with low-voltage DC — no VOC outgassing, IPA-safe and rated to over a million cycles, integrating with existing cleanroom partitions as a non-intrusive retrofit.

01
Glass faces — Laminated safety glass with ≥ 7H surface hardness; non-porous and easy to wipe down.
02
Electrochromic interlayer — Low-voltage DC interlayer switches transparency reversibly in < 1.2 seconds.
03
Low-VOC build — No VOC outgassing and IPA-disinfectant compatibility for contamination control.
04
Partition integration — Seamless integration with existing cleanroom partition systems as a non-intrusive retrofit.
03 — Why Specify It

Why Choose Our Atomized Glass Film

Instant privacy

Switches clear-to-opaque in < 1.2 s for on-demand visual privacy in Grade A/B zones.

No contaminant traps

Replaces blinds and curtains that harbor particulates in controlled environments.

Low-VOC & IPA-safe

No VOC outgassing and compatibility with IPA disinfectants protect clean processes.

Durable switching

Rated to over 1 million switch cycles with ≥ 7H scratch-resistant glass.

Fire-rated

BS 476 Class 0 / EN 13501-1 B-s1,d0 fire rating for regulated environments.

Easy retrofit

Non-intrusive integration with existing cleanroom glass partition systems.

04 — Where It's Used

Atomized Glass Film Applications

Specified as switchable privacy glazing across regulated and high-precision industries. See real cleanroom project case studies or browse the full cleanroom product range.

Atomized switchable glass film in a cleanroom partition
Switchable atomized glass providing instant privacy without blinds.
ISO 14644 & SIRIMCleanroom-grade quality
Stamped DatasheetAir-tightness & fire report
Malaysia-BasedLocal engineering team
7×24 Support10-year structural warranty

Get a project-specific quote in 24 hours

Send your cleanroom classification, floor area and finish requirements. Our Malaysia-based engineering team replies with a stamped datasheet, fire certificate and pricing — 7×24 technical support by email, phone or WhatsApp.

Request a Free Quote Chat on WhatsApp
1

Where should air showers be installed in a cleanroom?

 Install between changing rooms and clean areas, or between ISO 8/ISO 7 classified areas and unclean areas. Personnel pass through after changing into cleanroom clothing but before entering the controlled environment

2

What is involved in the construction of a modular cleanroom?

To assemble laboratory spaces efficiently, modular components are preferred. An assembled cleanroom utilizes prefabricated sections to reduce on-site construction time. The underlying aluminum profile system provides the necessary framework for mounting panels and doors, ensuring precision alignment and structural rigidity throughout the facility.

3

What are the key considerations for air shower design?

Selecting the right air shower requires careful planning. Proper air shower design ensures effective personnel decontamination before entering controlled environments. Specifications depend on room size. Consulting an experienced air shower manufacturer helps determine optimal placement. Compliance with standards is essential. Regular maintenance schedules must be established to sustain performance over time.

4

What defines quality in clean room door systems?

Sealing integrity is vital. air tight sliding clean room doors prevent pollutants from entering. Each air tight sliding cleanroom door must meet pressure ratings. Reputable air tight sliding cleanroom door manufacturers provide leakage certification. Automatic mechanisms reduce human contact risks. Material selection prioritizes durability and ease of cleaning to meet hygiene protocols. Installation requires precise alignment.

CONTACT
Address
A-17-11, Tower A, Pinnacle Petaling Jaya, Jalan Utara C, 46200 Petaling Jaya, Selangor, Malaysia
Contact Info
013 960 7988
Email
Info@wonclean.com
cleanroom map

Leave a Message

Leave a Message

We'd love to hear from you. Send us a message and we'll respond as soon as possible
X