Cleanroom FFU
Camsafe is a high-efficiency safety exhaust filter unit for ducts. Features fully welded housing tested at 5000Pa for airtightness. High-flatness sealing surface with filter gasket ensures leak-free performance. H14 filter meets ≥99.99% PAO/DEHS efficiency.
Request a Free Quote
The bag in / bag out equipment is a critical containment solution for high-integrity filtration systems where personnel safety, process purity and regulatory compliance are non-negotiable. Dual-port bagging sleeves, rigid frame seals and pressure-tested gasketing enable safe, contained change-out of spent HEPA/ULPA filters without exposure to hazardous aerosols, pathogens or ultrafine particulates.
Engineered for Malaysia biotech cleanrooms and Malaysia semiconductor cleanrooms, the BIBO housing integrates with our fan filter unit (FFU) range and is supplied as part of our Malaysia prefabricated cleanrooms programme.
Standard configuration for the Wonclean bag in / bag out equipment. Material, filter stages and pressure range are all customizable to project and containment requirements.
| Frame material | 316L stainless steel (electropolished) or anodized aluminum |
|---|---|
| Seal integrity | Leak rate ≤ 0.001% at 2500 Pa (IEST-RP-CC034.3) |
| Filter compatibility | HEPA H13–H14, ULPA U15–U17, carbon variants |
| Operating pressure | −2500 Pa to +2500 Pa |
| Bag materials | LDPE, Tyvek® 1073B, Chemprotex® 3000 |
| Airtightness testing | 5000 Pa, fully welded housing |
| Filter efficiency | ≥ 99.99% PAO/DEHS (H14) |
| Gaskets | ASTM D2000 BRM elastomeric, < 15% compression set over 5 years |
| Flange tolerance | ± 0.2 mm alignment |
| Compliance | ISO 14644-1 Class 3–8, FDA / TÜV SÜD audit-ready |
Values shown are standard/representative configurations. Confirm final certified figures (leak test, gas-tight validation) against the project datasheet before specification — Wonclean issues a stamped datasheet with every quotation.
The dual-port bagging sleeve is the engineering secret. A fully welded housing with high-flatness sealing surfaces and integrated filter gaskets lets operators change filters inside a sealed bag — passive mechanical assurance that needs no operator-dependent training, validated to 5000 Pa.
Filters are replaced without breaking isolation, protecting operators from hazardous aerosols.
Leak rate ≤ 0.001% at 2500 Pa and 5000 Pa airtightness testing on a fully welded housing.
Safe by design — no operator-dependent training required for compliant filter changes.
Supports HEPA, ULPA and carbon filters in single or multi-stage configurations.
Thermal-cycling resilience across 10,000+ cycles with < 15% gasket compression set over 5 years.
ISO 14644-1 with FDA / TÜV SÜD audit readiness for regulated and BSL-3 facilities.
Specified as safe-change containment filter housings across regulated and hazardous environments. See real cleanroom project case studies or browse the full cleanroom product range.
Send your cleanroom classification, floor area and finish requirements. Our Malaysia-based engineering team replies with a stamped datasheet, fire certificate and pricing — 7×24 technical support by email, phone or WhatsApp.
Request a Free Quote Chat on WhatsAppStanding still creates purification "dead spots" where airflow cannot reach areas like back, underarms, and knees. Active rotation (at least one full turn) with arm movements ensures complete surface exposure