Purified laminar flow cover is an air purification unit that can provide a locally clean environment,It can be installed flexibly above the process points requiring high cleanliness.

Request a Free Quote
ISO Class 5Class 100 work zone
H14 ULPA≥ 99.9995% @ 0.1 µm
Horizontal / Vertical±5% velocity uniformity
Shadow-Free LED≥ 500 lux, low noise

 

Clean Laminar Flow Hood: Localised ISO Class 5 Air Purification

The clean laminar flow hood (purified laminar flow cover) is an air-purification unit that delivers a local ISO Class 5 environment, installed flexibly above process points requiring high cleanliness. As experienced laminar flow hood manufacturers, we build both horizontal laminar air flow hood and vertical laminar flow cabinet configurations with HEPA/ULPA filtration and low-noise EC fans.

The hood integrates with our fan filter unit (FFU) range and is supplied as part of our Malaysia prefabricated cleanrooms programme.

01 — Technical Specifications

Clean Laminar Flow Hood Specifications

Standard configuration for the Wonclean clean laminar flow hood. Work area, flow direction and filter class are all customizable to project and cleanroom classification requirements.

Clean Laminar Flow Hood — Standard Technical Data
Work area dimensions 1200×600×600 mm
Airflow velocity 0.3–0.5 m/s (adjustable, ±5% uniformity)
Filter H14 ULPA (≥ 99.9995% @ 0.1 µm)
Construction 304 stainless work surface, anodised aluminium frame, tempered glass sash
Power supply 230 V AC, 50 Hz, 1.2 kW
Lighting LED ≥ 500 lux, shadow-free distribution
Flow direction Horizontal or vertical laminar flow
Options UV-C (254 nm), static-dissipative surface, touchless sash, data logging
Base Vibration-damped; tool-less fan access
Validation IEST-RP-CC002.3 · ISO 14644-3 · IEC 61000-6-3/4

Values shown are standard/representative configurations. Confirm final certified figures (airflow, filter integrity) against the project datasheet before specification — Wonclean issues a stamped datasheet with every quotation.

02 — Construction

Clean Laminar Flow Hood Construction

Consistent velocity profiling is the engineering secret. An H14 ULPA filter delivers unidirectional airflow across a 304 stainless work surface with minimal recirculation zones — vibration-damped, low-noise and serviceable via removable side panels and tool-less fan access.

01
ULPA filter — H14 ULPA (≥ 99.9995% @ 0.1 µm) delivering unidirectional laminar airflow.
02
Stainless work surface — 304 stainless steel work surface with optional static-dissipative finish.
03
Aluminium frame & sash — Anodised aluminium frame with tempered glass sash and shadow-free LED lighting.
04
Serviceable base — Vibration-damped base, low-noise fan and tool-less fan access for fast maintenance.
03 — Why Specify It

Why Choose Our Clean Laminar Flow Hood

ISO Class 5 work zone

H14 ULPA unidirectional airflow maintains Class 100 cleanliness over the work surface.

Uniform velocity

±5% velocity uniformity with minimal recirculation zones for repeatable results.

Flexible flow direction

Horizontal or vertical laminar flow to suit the process and operator ergonomics.

Shadow-free lighting

≥ 500 lux LED with shadow-free distribution for precise, low-fatigue work.

Quiet & serviceable

Low-noise fan with tool-less fan access and removable side panels for easy upkeep.

Smart options

Optional UV-C sterilization, touchless sash control and data-logging interface.

04 — Where It's Used

Clean Laminar Flow Hood Applications

Specified as ISO Class 5 clean benches across regulated and high-precision industries. See real cleanroom project case studies or browse the full cleanroom product range.

Clean laminar flow hood for ISO Class 5 work
ISO Class 5 clean laminar flow hood with H14 ULPA unidirectional airflow.
ISO 14644 & SIRIMCleanroom-grade quality
Stamped DatasheetAir-tightness & fire report
Malaysia-BasedLocal engineering team
7×24 Support10-year structural warranty

Get a project-specific quote in 24 hours

Send your cleanroom classification, floor area and finish requirements. Our Malaysia-based engineering team replies with a stamped datasheet, fire certificate and pricing — 7×24 technical support by email, phone or WhatsApp.

Request a Free Quote Chat on WhatsApp
1

Where should air showers be installed in a cleanroom?

 Install between changing rooms and clean areas, or between ISO 8/ISO 7 classified areas and unclean areas. Personnel pass through after changing into cleanroom clothing but before entering the controlled environment

2

What is involved in the construction of a modular cleanroom?

To assemble laboratory spaces efficiently, modular components are preferred. An assembled cleanroom utilizes prefabricated sections to reduce on-site construction time. The underlying aluminum profile system provides the necessary framework for mounting panels and doors, ensuring precision alignment and structural rigidity throughout the facility.

3

What are the key considerations for air shower design?

Selecting the right air shower requires careful planning. Proper air shower design ensures effective personnel decontamination before entering controlled environments. Specifications depend on room size. Consulting an experienced air shower manufacturer helps determine optimal placement. Compliance with standards is essential. Regular maintenance schedules must be established to sustain performance over time.

4

What defines quality in clean room door systems?

Sealing integrity is vital. air tight sliding clean room doors prevent pollutants from entering. Each air tight sliding cleanroom door must meet pressure ratings. Reputable air tight sliding cleanroom door manufacturers provide leakage certification. Automatic mechanisms reduce human contact risks. Material selection prioritizes durability and ease of cleaning to meet hygiene protocols. Installation requires precise alignment.

CONTACT
Address
A-17-11, Tower A, Pinnacle Petaling Jaya, Jalan Utara C, 46200 Petaling Jaya, Selangor, Malaysia
Contact Info
013 960 7988
Email
Info@wonclean.com
cleanroom map

Leave a Message

Leave a Message

We'd love to hear from you. Send us a message and we'll respond as soon as possible
X