youtube twitter facebook linkedin
Info@wonclean.com / 013 960 7988

Cleanroom Other products

Cleanroom ceiling panel system

The clean room ceiling panel is an important part of the clean room system. It is usually used in clean room projects where the cleanliness level is relatively high, for example, Class 100, Class 1000, 100000. It is widely used in the electronics industry, chemical industry, military industry, etc.

Request a Free Quote
Hidden-Bar CeilingSeamless flush face
150 kg/m² LoadHEPA/ULPA-ready
Class B-s1,d0EN 13501-1 fire
ISO 14644Class 5–8 ready

Clean Room Ceiling Panel System: Seamless Hidden-Bar Cleanroom Ceilings

The clean room ceiling panel system is an essential part of any high-grade cleanroom, used where the cleanliness level is demanding — Class 100, 1,000 and 100,000 — across electronics, chemical, military, semiconductor and biopharmaceutical facilities. Its seamless hiding bar ceiling architecture conceals the support rails so only a smooth, particle-tight ceiling face is visible.

As a trusted Malaysia cleanroom manufacturer, we finish the system with durable hpl ceiling panels and integrate it with our aluminum honeycomb cleanroom panel, HPL sandwich panel and clean room partition panels — all delivered within our prefabricated modular cleanrooms programme.

01 — Technical Specifications

Clean Room Ceiling Panel System Specifications

Standard configuration for the Wonclean clean room ceiling panel system. Core, facing, load rating and grid are all customizable to project and cleanroom classification requirements.

Clean Room Ceiling Panel System — Standard Technical Data
Panel core Aluminum honeycomb + PU foam (42 kg/m³), zero-VOC (HPL-faced PU core option) · ISO 14644-8 Annex D
Surface finish Electrostatic epoxy-polyester (20–30 GU) (EN 438-3 HPL 1.0 mm option) · resists 70% IPA, hypochlorite, steam
Fire rating EN 13501-1 Class B-s1,d0 · ASTM E84 & BS 476 Part 7 validated
Load capacity 120 kg/m² static (150 kg/m² HPL-reinforced option) · HEPA/ULPA modules up to 1200×600 mm
Ceiling grid Concealed anodized Al 6063-T5 rails, pre-drilled, ≤ 0.5 mm level variance
Dimensional tolerance ± 0.3 mm over 3 m (± 0.25 mm HPL-reinforced option)
Cleanliness ISO 14644-1 Class 5–8 (Class 100 / 1,000 / 100,000)
Warranty 10-year structural warranty
Compliance ISO 9001/14001 · SIRIM QAS · CE

Values shown are standard/representative configurations. Confirm final certified figures (fire test, load rating) against the project datasheet before specification — Wonclean issues a stamped datasheet with every quotation.

02 — Construction

Clean Room Ceiling Panel System Construction

A concealed-rail (hidden-bar) suspension carries honeycomb-cored ceiling panels on a pre-drilled, level-set anodized grid — producing a continuous, flush ceiling plane with no exposed T-bars to trap particulates.

01
Ceiling face — Epoxy-polyester or EN 438-3 HPL skin; non-porous, chemical- and steam-resistant for repeated wipe-down.
02
Honeycomb core — Aluminum honeycomb + PU foam (42 kg/m³), zero-VOC, lightweight yet stiff with high flatness.
03
Concealed grid — Anodized Al 6063-T5 hidden-bar rails, pre-drilled with ≤ 0.5 mm level variance for gasket compression.
04
Integrated services — Cut-outs for HEPA/ULPA modules, flush lighting and sensors at up to 150 kg/m² static load.
03 — Why Specify It

Why Choose Our Clean Room Ceiling Panel System

Seamless hidden-bar face

Concealed rails leave a flush, particle-tight ceiling plane with no exposed T-bars to harbour contaminants.

High load capacity

Up to 150 kg/m² static load supports HEPA/ULPA modules, lighting and services without sag.

Class B-s1,d0 fire

EN 13501-1 fire performance validated to ASTM E84 and BS 476 Part 7.

Chemical-resistant surface

HPL and epoxy faces resist 70% IPA, sodium hypochlorite and steam for aggressive wipe-down.

Precision flatness

±0.3 mm tolerance and ≤ 0.5 mm level variance for reliable gasket sealing.

10-year warranty

Anodized framing and tight tolerances backed by a 10-year structural warranty.

04 — Where It's Used

Clean Room Ceiling Panel System Applications

Specified as the ceiling plane for high-grade cleanrooms across regulated and high-precision industries. See real cleanroom project case studies or browse the full cleanroom product range.

Clean room ceiling panel system with concealed hidden-bar grid
Hidden-bar clean room ceiling panel system with flush HEPA-ready face.
ISO 14644 & SIRIMCleanroom-grade quality
Stamped DatasheetAir-tightness & fire report
Malaysia-BasedLocal engineering team
7×24 Support10-year structural warranty

Get a project-specific quote in 24 hours

Send your cleanroom classification, floor area and finish requirements. Our Malaysia-based engineering team replies with a stamped datasheet, fire certificate and pricing — 7×24 technical support by email, phone or WhatsApp.

Request a Free Quote Chat on WhatsApp
1

Where should air showers be installed in a cleanroom?

 Install between changing rooms and clean areas, or between ISO 8/ISO 7 classified areas and unclean areas. Personnel pass through after changing into cleanroom clothing but before entering the controlled environment

2

What is involved in the construction of a modular cleanroom?

To assemble laboratory spaces efficiently, modular components are preferred. An assembled cleanroom utilizes prefabricated sections to reduce on-site construction time. The underlying aluminum profile system provides the necessary framework for mounting panels and doors, ensuring precision alignment and structural rigidity throughout the facility.

3

What are the key considerations for air shower design?

Selecting the right air shower requires careful planning. Proper air shower design ensures effective personnel decontamination before entering controlled environments. Specifications depend on room size. Consulting an experienced air shower manufacturer helps determine optimal placement. Compliance with standards is essential. Regular maintenance schedules must be established to sustain performance over time.

4

What defines quality in clean room door systems?

Sealing integrity is vital. air tight sliding clean room doors prevent pollutants from entering. Each air tight sliding cleanroom door must meet pressure ratings. Reputable air tight sliding cleanroom door manufacturers provide leakage certification. Automatic mechanisms reduce human contact risks. Material selection prioritizes durability and ease of cleaning to meet hygiene protocols. Installation requires precise alignment.

CONTACT
Address
A-17-11, Tower A, Pinnacle Petaling Jaya, Jalan Utara C, 46200 Petaling Jaya, Selangor, Malaysia
Contact Info
013 960 7988
Email
Info@wonclean.com
cleanroom map

Leave a Message

Leave a Message

We'd love to hear from you. Send us a message and we'll respond as soon as possible
X