youtube twitter facebook linkedin
Info@wonclean.com / 013 960 7988

Cleanroom Other products

Cleanroom weighing cover

The weighing cover is a kind of local purification equipment specially used in pharmaceutical, microbial research and scientific experiments place special local purification equipment...

Request a Free Quote
H14 Laminar Downflow0.45 m/s ±10%
Anti-StaticGrounded base + ionizer
Vibration-IsolatedISO 20483 Class B
USP <797>/<800>ISO Class 5–8

 

Cleanroom Weighing Cover: Local Containment for Dispensing & Weighing

The cleanroom weighing cover (weighing protection hood) is a local purification unit for pharmaceutical, microbial-research and laboratory dispensing, drawing HEPA-filtered downflow over the weighing zone to protect both product and operator from airborne particulates and active powders.

It complements our clean laminar flow hood and clean room partition panels, supplied within our Malaysia prefabricated cleanrooms programme.

01 — Technical Specifications

Cleanroom Weighing Cover Specifications

Standard configuration for the Wonclean cleanroom weighing cover. Size, filtration and static control are all customizable to project and cleanroom classification requirements.

Cleanroom Weighing Cover — Standard Technical Data
Internal dimensions 600×450×500 mm (custom to 1200×800×700 mm)
Frame & panels 316L stainless frame, 10 mm anti-static polycarbonate, anodized aluminum plenum
HEPA filtration H14 (99.995% @ 0.1 µm); vertical downflow 0.45 m/s ±10%
Static control Grounded conductive base (optional ionizer ±50 V, <±2 V drift)
Panel resistivity 10⁶–10⁹ Ω/sq (anti-static polycarbonate)
Weight capacity up to 30 kg on internal platform
Vibration isolation ISO 20483 Class B compliant
Filter service Tool-free HEPA replacement under 8 minutes
Ingress protection IP54 on electrical interfaces
Certifications CE, IEC 61000-6-2/3, UL 61010-1

Values shown are standard/representative configurations. Confirm final certified figures (airflow, static performance) against the project datasheet before specification — Wonclean issues a stamped datasheet with every quotation.

02 — Construction

Cleanroom Weighing Cover Construction

Vibration isolation and static control are the engineering secret. A 316L frame with anti-static polycarbonate panels and H14 vertical downflow shields the balance from turbulence and charge — ISO 20483 Class B vibration isolation keeps micro-weighing repeatable and traceable.

01
Aluminum plenum — Anodized aluminum top plenum housing the H14 HEPA filter for vertical laminar downflow.
02
Anti-static panels — 10 mm anti-static polycarbonate (10⁶–10⁹ Ω/sq), UV-stabilized and abrasion-resistant.
03
316L frame — 316L stainless steel frame with grounded conductive base and optional ionizer.
04
Vibration isolation — ISO 20483 Class B vibration isolation with adjustable anchor brackets to cleanroom panels.
03 — Why Specify It

Why Choose Our Cleanroom Weighing Cover

Stable micro-weighing

H14 laminar downflow and vibration isolation deliver repeatable, traceable mass measurement.

Static-free measurement

Grounded base and optional ionizer eliminate electrostatic interference on the balance.

Clear visibility

Anti-static polycarbonate panels keep the weighing zone visible and easy to clean.

Fast filter service

Tool-free HEPA replacement in under 8 minutes minimizes downtime.

Easy integration

Adjustable anchor brackets mount directly to prefabricated cleanroom infrastructure.

Long service life

15+ years of continuous 24/7 operation with IP54-protected electrical interfaces.

04 — Where It's Used

Cleanroom Weighing Cover Applications

Specified for analytical and dispensing weighing zones across regulated industries. See real cleanroom project case studies or browse the full cleanroom product range.

Cleanroom weighing cover protecting an analytical balance
HEPA laminar-flow weighing cover isolating micro-balances from particulates and static.
ISO 14644 & SIRIMCleanroom-grade quality
Stamped DatasheetAir-tightness & fire report
Malaysia-BasedLocal engineering team
7×24 Support10-year structural warranty

Get a project-specific quote in 24 hours

Send your cleanroom classification, floor area and finish requirements. Our Malaysia-based engineering team replies with a stamped datasheet, fire certificate and pricing — 7×24 technical support by email, phone or WhatsApp.

Request a Free Quote Chat on WhatsApp
1

Where should air showers be installed in a cleanroom?

 Install between changing rooms and clean areas, or between ISO 8/ISO 7 classified areas and unclean areas. Personnel pass through after changing into cleanroom clothing but before entering the controlled environment

2

What is involved in the construction of a modular cleanroom?

To assemble laboratory spaces efficiently, modular components are preferred. An assembled cleanroom utilizes prefabricated sections to reduce on-site construction time. The underlying aluminum profile system provides the necessary framework for mounting panels and doors, ensuring precision alignment and structural rigidity throughout the facility.

3

What are the key considerations for air shower design?

Selecting the right air shower requires careful planning. Proper air shower design ensures effective personnel decontamination before entering controlled environments. Specifications depend on room size. Consulting an experienced air shower manufacturer helps determine optimal placement. Compliance with standards is essential. Regular maintenance schedules must be established to sustain performance over time.

4

What defines quality in clean room door systems?

Sealing integrity is vital. air tight sliding clean room doors prevent pollutants from entering. Each air tight sliding cleanroom door must meet pressure ratings. Reputable air tight sliding cleanroom door manufacturers provide leakage certification. Automatic mechanisms reduce human contact risks. Material selection prioritizes durability and ease of cleaning to meet hygiene protocols. Installation requires precise alignment.

CONTACT
Address
A-17-11, Tower A, Pinnacle Petaling Jaya, Jalan Utara C, 46200 Petaling Jaya, Selangor, Malaysia
Contact Info
013 960 7988
Email
Info@wonclean.com
cleanroom map

Leave a Message

Leave a Message

We'd love to hear from you. Send us a message and we'll respond as soon as possible
X