youtube twitter facebook linkedin
Info@wonclean.com / 013 960 7988

Cleanroom Other products

EPS cleanroom panel

As a vertically integrated Malaysia cleanroom wall panels manufacturers, we offer full traceability, third-party FM/UL certification, and ASEAN-wide logistics — making us the preferred cleanroom panels partner for engineering teams who prioritize compliance, speed-to-operational, and lifecycle durability over lowest-bid procurement.

Request a Free Quote
Lightweight EPSLow-cost, easy handling
Class A FireASTM E84 rated
Non-SheddingSealed coated facing
ISO 14644Class 3–8 ready

 

EPS Cleanroom Panel: Cost-Effective Insulated Cleanroom Walls

As a vertically integrated Malaysia cleanroom wall panels manufacturer, we build the EPS cleanroom panel with full traceability and third-party certification — a cost-effective cleanroom panel wall system for walls and ceilings where lightweight insulation and clean, non-shedding surfaces matter.

It sits within our complete panel range alongside the clean room aluminum honeycomb panel, HPL sandwich panel and PIR cleanroom panel — supplied by experienced hpl panels manufacturers.

01 — Technical Specifications

EPS Cleanroom Panel Specifications

Standard configuration for the Wonclean EPS cleanroom panel. Core density, facing and thickness are all customizable to project and cleanroom classification requirements.

EPS Cleanroom Panel — Standard Technical Data
Panel type EPS-core composite sandwich panel
Core material Expanded polystyrene (EPS), density ≥ 18 kg/m³
Surface finish Electrostatic epoxy-polyester coating (gloss 70 ± 5)
Standard thickness 50 / 75 / 100 mm
Fire rating ASTM E84 Class A (flame spread ≤ 25)
Thermal conductivity ≈ 0.036–0.039 W/m·K
Particle shedding ≤ 10 particles/m³ @ 0.5 µm
Peel strength > 12 N/mm
Optional skins Fiberglass-reinforced for impact resistance
Compliance ISO 14644 · MS 1064 · FM/UL certification
Cleanliness grade ISO 14644-1 Class 3–8 ready

Values shown are standard/representative configurations. Confirm final certified figures (fire test report, load rating) against the project datasheet before specification — Wonclean issues a stamped datasheet with every quotation.

02 — Construction

EPS Cleanroom Panel Construction

A lightweight EPS core between electrostatically coated facings keeps panel weight low while maintaining a sealed, non-shedding envelope. Factory-tested joints (ISO 14644-3) lock out the gaps that compromise classified environments — and the modular build supports fast reconfiguration.

01
Coated facing — Electrostatically applied epoxy-polyester coating; smooth, non-porous, easy-clean cleanroom surface.
02
EPS core — Expanded polystyrene ≥ 18 kg/m³ for lightweight strength and thermal insulation.
03
Inner facing — Matched coated skin forms a fully sealed, non-shedding two-sided cleanroom surface.
04
Optional reinforcement — Fiberglass-reinforced skins for added impact resistance in high-traffic areas.
03 — Why Specify It

Why Choose Our EPS Cleanroom Panels

Lightweight & economical

The low-density EPS core cuts panel weight and cost, easing handling and speeding installation.

Class A fire performance

ASTM E84 Class A facing with non-combustible core options for regulated cleanroom environments.

Non-shedding surface

Sealed epoxy-polyester coating keeps particle shedding ≤ 10/m³ @ 0.5 µm for ISO-classified spaces.

Strong adhesion

Peel strength > 12 N/mm ensures durable facing-to-core bonding over the panel's service life.

Modular & reconfigurable

Factory-tested joints and a modular system allow fast cleanroom reconfiguration and expansion.

Certified & traceable

ISO 14644, MS 1064 and FM/UL certification with full material traceability and turnkey support.

04 — Where It's Used

EPS Cleanroom Panel Applications

Specified as cleanroom wall panels, ceiling panels and partition systems across regulated and high-precision industries. See real cleanroom project case studies or browse the full cleanroom product range.

ISO 14644 & SIRIMCleanroom-grade quality
Stamped DatasheetAir-tightness & fire report
Malaysia-BasedLocal engineering team
7×24 Support10-year structural warranty

Get a project-specific quote in 24 hours

Send your cleanroom classification, floor area and finish requirements. Our Malaysia-based engineering team replies with a stamped datasheet, fire certificate and pricing — 7×24 technical support by email, phone or WhatsApp.

Request a Free Quote Chat on WhatsApp
1

Where should air showers be installed in a cleanroom?

 Install between changing rooms and clean areas, or between ISO 8/ISO 7 classified areas and unclean areas. Personnel pass through after changing into cleanroom clothing but before entering the controlled environment

2

What is involved in the construction of a modular cleanroom?

To assemble laboratory spaces efficiently, modular components are preferred. An assembled cleanroom utilizes prefabricated sections to reduce on-site construction time. The underlying aluminum profile system provides the necessary framework for mounting panels and doors, ensuring precision alignment and structural rigidity throughout the facility.

3

What are the key considerations for air shower design?

Selecting the right air shower requires careful planning. Proper air shower design ensures effective personnel decontamination before entering controlled environments. Specifications depend on room size. Consulting an experienced air shower manufacturer helps determine optimal placement. Compliance with standards is essential. Regular maintenance schedules must be established to sustain performance over time.

4

What defines quality in clean room door systems?

Sealing integrity is vital. air tight sliding clean room doors prevent pollutants from entering. Each air tight sliding cleanroom door must meet pressure ratings. Reputable air tight sliding cleanroom door manufacturers provide leakage certification. Automatic mechanisms reduce human contact risks. Material selection prioritizes durability and ease of cleaning to meet hygiene protocols. Installation requires precise alignment.

CONTACT
Address
A-17-11, Tower A, Pinnacle Petaling Jaya, Jalan Utara C, 46200 Petaling Jaya, Selangor, Malaysia
Contact Info
013 960 7988
Email
Info@wonclean.com
cleanroom map

Leave a Message

Leave a Message

We'd love to hear from you. Send us a message and we'll respond as soon as possible
X