youtube twitter facebook linkedin
Info@wonclean.com / 013 960 7988

Cleanroom Other products

Medical clean panel

Medical clean panel is based on medium-density fiber cement panel, UV paint is used as raw material, and the surface of the panel is painted and decorated by UV light curing process....

Request a Free Quote
Silver-Ion Antibacterial>99.9% MRSA reduction
Seamless Non-PorousResists microbial growth
Class A FireASTM E84 rated
USP <797>ISO 14644 Class 3–8

 

Medical Clean Panel: Antibacterial UV-Cured Wall Panel for Healthcare

The medical clean panel is based on a medium-density fibre-cement board finished with UV-cured paint, giving a smooth, medical antibacterial wall panel surface that withstands repeated disinfection. It is ideal for hospitals, operating theatres and medical lab wall panels requiring hygienic, easy-clean cladding.

It is offered alongside our HPL sandwich panel and clean room partition panels, and complements our metal laboratory furniture range.

01 — Technical Specifications

Medical Clean Panel Specifications

Standard configuration for the Wonclean medical clean panel. Facing, core and antibacterial finish are all customizable to project and cleanroom classification requirements.

Medical Clean Panel — Standard Technical Data
Panel type Antibacterial PU-core medical cleanroom panel
Core material Closed-cell polyurethane, density ≥ 42 kg/m³ (ISO 10967)
Face sheets 0.5 mm SS304/316 or 1.0 mm anodized aluminum
Antibacterial coating Silver-ion · > 99.9% MRSA & P. aeruginosa in 2 h
Fire rating ASTM E84 Class A (flame ≤ 25, smoke ≤ 50)
Thermal conductivity ≈ 0.022 W/m·K (23°C)
Surface roughness ≤ 0.8 µm (steel) / ≤ 1.2 µm (aluminum)
Joint system Tongue-and-groove with EPDM gasket (ISO 14644-3)
Outgassing < 0.1 µg/g VOC
Dimensional stability ± 0.15 mm/m (25–40°C range)
Air-tightness ≤ 0.5 Pa pressure decay (5 min)
Cleanliness grade ISO 14644-1 Class 3–8 · USP <797>

Values shown are standard/representative configurations. Confirm final certified figures (fire test report, antibacterial test, air-tightness) against the project datasheet before specification — Wonclean issues a stamped datasheet with every quotation.

02 — Construction

Medical Clean Panel Construction

The silver-ion antibacterial facing is the engineering secret. Non-porous metal skins over a closed-cell PU core create a seamless, non-shedding barrier that resists microbial colonization — achieving > 99.9% reduction of MRSA and Pseudomonas aeruginosa within two hours.

01
Antibacterial facing — 0.5 mm SS304/316 or 1.0 mm anodized aluminum with silver-ion coating; non-porous, easy-clean barrier.
02
Closed-cell PU core — Polyurethane ≥ 42 kg/m³ for low thermal conductivity, rigidity and dimensional stability.
03
Inner facing — Matched metal skin forms a sealed, low-outgassing (< 0.1 µg/g VOC) two-sided surface.
04
Sealed gasket joint — Continuous tongue-and-groove with EPDM gasket, silicone-free sealant compatible.
03 — Why Specify It

Why Choose Our Medical Clean Panels

Active antibacterial surface

Silver-ion coating reduces MRSA and Pseudomonas aeruginosa by > 99.9% within two hours for infection control.

Seamless & non-porous

Smooth metal facings and gasketed joints prevent particle shedding and microbial colonization.

Low-outgassing purity

< 0.1 µg/g VOC protects photoresist and sensitive medical and semiconductor processes.

Class A fire safety

ASTM E84 Class A facing with low smoke for safe, regulated medical and aseptic environments.

FFU & grid integration

Seamless integration with ceiling grids and FFU systems for a clean, flush medical envelope.

Lower cleaning labor

Non-porous antibacterial surfaces cut cleaning labor by 35% with a 15+ year service life.

04 — Where It's Used

Medical Clean Panel Applications

Specified as medical cleanroom wall panels, ceiling panels and partition systems across hospitals, laboratories and regulated industries. See real cleanroom project case studies or browse the full cleanroom product range.

Medical clean panels installed as antibacterial cleanroom walls and partitions
Antibacterial medical clean panels installed as cleanroom wall and ceiling systems.
ISO 14644 & SIRIMCleanroom-grade quality
Stamped DatasheetAir-tightness & fire report
Malaysia-BasedLocal engineering team
7×24 Support10-year structural warranty

Get a project-specific quote in 24 hours

Send your cleanroom classification, floor area and finish requirements. Our Malaysia-based engineering team replies with a stamped datasheet, fire certificate and pricing — 7×24 technical support by email, phone or WhatsApp.

Request a Free Quote Chat on WhatsApp
1

Where should air showers be installed in a cleanroom?

 Install between changing rooms and clean areas, or between ISO 8/ISO 7 classified areas and unclean areas. Personnel pass through after changing into cleanroom clothing but before entering the controlled environment

2

What is involved in the construction of a modular cleanroom?

To assemble laboratory spaces efficiently, modular components are preferred. An assembled cleanroom utilizes prefabricated sections to reduce on-site construction time. The underlying aluminum profile system provides the necessary framework for mounting panels and doors, ensuring precision alignment and structural rigidity throughout the facility.

3

What are the key considerations for air shower design?

Selecting the right air shower requires careful planning. Proper air shower design ensures effective personnel decontamination before entering controlled environments. Specifications depend on room size. Consulting an experienced air shower manufacturer helps determine optimal placement. Compliance with standards is essential. Regular maintenance schedules must be established to sustain performance over time.

4

What defines quality in clean room door systems?

Sealing integrity is vital. air tight sliding clean room doors prevent pollutants from entering. Each air tight sliding cleanroom door must meet pressure ratings. Reputable air tight sliding cleanroom door manufacturers provide leakage certification. Automatic mechanisms reduce human contact risks. Material selection prioritizes durability and ease of cleaning to meet hygiene protocols. Installation requires precise alignment.

CONTACT
Address
A-17-11, Tower A, Pinnacle Petaling Jaya, Jalan Utara C, 46200 Petaling Jaya, Selangor, Malaysia
Contact Info
013 960 7988
Email
Info@wonclean.com
cleanroom map

Leave a Message

Leave a Message

We'd love to hear from you. Send us a message and we'll respond as soon as possible
X